Abstract

Objective: To determine the efficacy of individual fetal heart rate (FHR) indices, as determined by computer analysis of the FHR tracing, in detecting fetal acidemia at birth in growth-restricted fetuses. Methods: The study population consisted of 38 growth-restricted fetuses at 26-37 weeks' gestation from pregnancies with abnormal uterine and/or umbilical artery Doppler velocimetry. The 1-hour FHR tracing was analyzed by computer within 4 hours of cesarean birth before the onset of labor. Umbilical artery cord blood was collected at birth, and pH was determined within 5 minutes of collection. Results: On linear regression, the duration of episodes of low variation in minutes (r = -0.77, r2 = 0.59) and short-term (r = 0.72, r2 = 0.52) and long-term (r = 0.69, r2 = 0.47) variation in milliseconds were significantly related to umbilical artery pH at birth, and more so than the number of accelerations of ten (r = 0.57, r2 = 0.32) and 15 (r = 0.38, r2 = 0.14) beats per minute. There were significant differences in computer measurements of FHR accelerations and variation between the umbilical artery pH categories of acidemia (pH less than 7.20), preacidemia (7.20-7.25), and nonacidemia (greater than 7.25). Stepwise regression revealed that episodes of low variation best described the model for predicting umbilical artery pH at birth (P < .001), with no improvement provided by the addition of other computer-analyzed FHR characteristics. Conclusion: In this population of growth-restricted fetuses delivered by elective cesarean, the computer indices of duration of episodes of low variation and short-term and long- term variation were significantly associated with umbilical artery pH and predicted umbilical artery acidemia at birth.

Original languageEnglish (US)
Pages (from-to)969-974
Number of pages6
JournalObstetrics and Gynecology
Volume87
Issue number6
DOIs
StatePublished - Jan 1 1996

Fingerprint

Umbilical Arteries
Fetal Heart Rate
Fetus
Heart Rate
Parturition
Growth
Labor Onset
Uterine Artery
Pregnancy
Rheology
Population Growth
Fetal Blood
Linear Models
Population

All Science Journal Classification (ASJC) codes

  • Obstetrics and Gynecology

Cite this

Guzman, Edwin R. ; Vintzileos, Anthony M. ; Martins, Maria ; Benito, Carlos ; Houlihan, Christopher ; Hanley, Maryellen. / The efficacy of individual computer heart rate indices in detecting acidemia at birth in growth-restricted fetuses. In: Obstetrics and Gynecology. 1996 ; Vol. 87, No. 6. pp. 969-974.
@article{39523eb96a714f399ee3c5cc2c26d150,
title = "The efficacy of individual computer heart rate indices in detecting acidemia at birth in growth-restricted fetuses",
abstract = "Objective: To determine the efficacy of individual fetal heart rate (FHR) indices, as determined by computer analysis of the FHR tracing, in detecting fetal acidemia at birth in growth-restricted fetuses. Methods: The study population consisted of 38 growth-restricted fetuses at 26-37 weeks' gestation from pregnancies with abnormal uterine and/or umbilical artery Doppler velocimetry. The 1-hour FHR tracing was analyzed by computer within 4 hours of cesarean birth before the onset of labor. Umbilical artery cord blood was collected at birth, and pH was determined within 5 minutes of collection. Results: On linear regression, the duration of episodes of low variation in minutes (r = -0.77, r2 = 0.59) and short-term (r = 0.72, r2 = 0.52) and long-term (r = 0.69, r2 = 0.47) variation in milliseconds were significantly related to umbilical artery pH at birth, and more so than the number of accelerations of ten (r = 0.57, r2 = 0.32) and 15 (r = 0.38, r2 = 0.14) beats per minute. There were significant differences in computer measurements of FHR accelerations and variation between the umbilical artery pH categories of acidemia (pH less than 7.20), preacidemia (7.20-7.25), and nonacidemia (greater than 7.25). Stepwise regression revealed that episodes of low variation best described the model for predicting umbilical artery pH at birth (P < .001), with no improvement provided by the addition of other computer-analyzed FHR characteristics. Conclusion: In this population of growth-restricted fetuses delivered by elective cesarean, the computer indices of duration of episodes of low variation and short-term and long- term variation were significantly associated with umbilical artery pH and predicted umbilical artery acidemia at birth.",
author = "Guzman, {Edwin R.} and Vintzileos, {Anthony M.} and Maria Martins and Carlos Benito and Christopher Houlihan and Maryellen Hanley",
year = "1996",
month = "1",
day = "1",
doi = "10.1016/0029-7844(96)00020-8",
language = "English (US)",
volume = "87",
pages = "969--974",
journal = "Obstetrics and Gynecology",
issn = "0029-7844",
publisher = "Lippincott Williams and Wilkins",
number = "6",

}

The efficacy of individual computer heart rate indices in detecting acidemia at birth in growth-restricted fetuses. / Guzman, Edwin R.; Vintzileos, Anthony M.; Martins, Maria; Benito, Carlos; Houlihan, Christopher; Hanley, Maryellen.

In: Obstetrics and Gynecology, Vol. 87, No. 6, 01.01.1996, p. 969-974.

Research output: Contribution to journalArticle

TY - JOUR

T1 - The efficacy of individual computer heart rate indices in detecting acidemia at birth in growth-restricted fetuses

AU - Guzman, Edwin R.

AU - Vintzileos, Anthony M.

AU - Martins, Maria

AU - Benito, Carlos

AU - Houlihan, Christopher

AU - Hanley, Maryellen

PY - 1996/1/1

Y1 - 1996/1/1

N2 - Objective: To determine the efficacy of individual fetal heart rate (FHR) indices, as determined by computer analysis of the FHR tracing, in detecting fetal acidemia at birth in growth-restricted fetuses. Methods: The study population consisted of 38 growth-restricted fetuses at 26-37 weeks' gestation from pregnancies with abnormal uterine and/or umbilical artery Doppler velocimetry. The 1-hour FHR tracing was analyzed by computer within 4 hours of cesarean birth before the onset of labor. Umbilical artery cord blood was collected at birth, and pH was determined within 5 minutes of collection. Results: On linear regression, the duration of episodes of low variation in minutes (r = -0.77, r2 = 0.59) and short-term (r = 0.72, r2 = 0.52) and long-term (r = 0.69, r2 = 0.47) variation in milliseconds were significantly related to umbilical artery pH at birth, and more so than the number of accelerations of ten (r = 0.57, r2 = 0.32) and 15 (r = 0.38, r2 = 0.14) beats per minute. There were significant differences in computer measurements of FHR accelerations and variation between the umbilical artery pH categories of acidemia (pH less than 7.20), preacidemia (7.20-7.25), and nonacidemia (greater than 7.25). Stepwise regression revealed that episodes of low variation best described the model for predicting umbilical artery pH at birth (P < .001), with no improvement provided by the addition of other computer-analyzed FHR characteristics. Conclusion: In this population of growth-restricted fetuses delivered by elective cesarean, the computer indices of duration of episodes of low variation and short-term and long- term variation were significantly associated with umbilical artery pH and predicted umbilical artery acidemia at birth.

AB - Objective: To determine the efficacy of individual fetal heart rate (FHR) indices, as determined by computer analysis of the FHR tracing, in detecting fetal acidemia at birth in growth-restricted fetuses. Methods: The study population consisted of 38 growth-restricted fetuses at 26-37 weeks' gestation from pregnancies with abnormal uterine and/or umbilical artery Doppler velocimetry. The 1-hour FHR tracing was analyzed by computer within 4 hours of cesarean birth before the onset of labor. Umbilical artery cord blood was collected at birth, and pH was determined within 5 minutes of collection. Results: On linear regression, the duration of episodes of low variation in minutes (r = -0.77, r2 = 0.59) and short-term (r = 0.72, r2 = 0.52) and long-term (r = 0.69, r2 = 0.47) variation in milliseconds were significantly related to umbilical artery pH at birth, and more so than the number of accelerations of ten (r = 0.57, r2 = 0.32) and 15 (r = 0.38, r2 = 0.14) beats per minute. There were significant differences in computer measurements of FHR accelerations and variation between the umbilical artery pH categories of acidemia (pH less than 7.20), preacidemia (7.20-7.25), and nonacidemia (greater than 7.25). Stepwise regression revealed that episodes of low variation best described the model for predicting umbilical artery pH at birth (P < .001), with no improvement provided by the addition of other computer-analyzed FHR characteristics. Conclusion: In this population of growth-restricted fetuses delivered by elective cesarean, the computer indices of duration of episodes of low variation and short-term and long- term variation were significantly associated with umbilical artery pH and predicted umbilical artery acidemia at birth.

UR - http://www.scopus.com/inward/record.url?scp=0029951468&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029951468&partnerID=8YFLogxK

U2 - 10.1016/0029-7844(96)00020-8

DO - 10.1016/0029-7844(96)00020-8

M3 - Article

C2 - 8649708

AN - SCOPUS:0029951468

VL - 87

SP - 969

EP - 974

JO - Obstetrics and Gynecology

JF - Obstetrics and Gynecology

SN - 0029-7844

IS - 6

ER -