Management of cardiac arrhythmias: Physiologic pacing in 1992

S. L. Winters, J. A. Gomes, J. Ip, J. S. Banas, U. Shagong, J. Camunas

Research output: Contribution to journalReview article

Abstract

Dual-chamber DDD-mode pacing has become the universal cardiac pacing mode. While dual-chamber pacemakers were gaining acceptance, adaptive-rate pacing was being developed. Adaptive-rate pacemakers increase pacing rates either when atrial activity cannot be sensed or when sinus node chronotropic incompetence is present. The most commonly used sensors are piezoelectric crystals, which respond to muscle vibrations; metabolic-responsive sensors, which sense changes in minute volume; and temperature sensors, which respond to changes in central venous temperature.

Original languageEnglish (US)
Pages (from-to)42-55
Number of pages14
JournalPrimary Cardiology
Volume18
Issue number2
StatePublished - Jan 1 1992
Externally publishedYes

Fingerprint

Cardiac Arrhythmias
Dichlorodiphenyldichloroethane
Sinoatrial Node
Temperature
Vibration
Muscles

All Science Journal Classification (ASJC) codes

  • Cardiology and Cardiovascular Medicine

Cite this

Winters, S. L., Gomes, J. A., Ip, J., Banas, J. S., Shagong, U., & Camunas, J. (1992). Management of cardiac arrhythmias: Physiologic pacing in 1992. Primary Cardiology, 18(2), 42-55.
Winters, S. L. ; Gomes, J. A. ; Ip, J. ; Banas, J. S. ; Shagong, U. ; Camunas, J. / Management of cardiac arrhythmias : Physiologic pacing in 1992. In: Primary Cardiology. 1992 ; Vol. 18, No. 2. pp. 42-55.
@article{ca530c24bbb049ceb980c0083a6eeef9,
title = "Management of cardiac arrhythmias: Physiologic pacing in 1992",
abstract = "Dual-chamber DDD-mode pacing has become the universal cardiac pacing mode. While dual-chamber pacemakers were gaining acceptance, adaptive-rate pacing was being developed. Adaptive-rate pacemakers increase pacing rates either when atrial activity cannot be sensed or when sinus node chronotropic incompetence is present. The most commonly used sensors are piezoelectric crystals, which respond to muscle vibrations; metabolic-responsive sensors, which sense changes in minute volume; and temperature sensors, which respond to changes in central venous temperature.",
author = "Winters, {S. L.} and Gomes, {J. A.} and J. Ip and Banas, {J. S.} and U. Shagong and J. Camunas",
year = "1992",
month = "1",
day = "1",
language = "English (US)",
volume = "18",
pages = "42--55",
journal = "Primary Cardiology",
issn = "0363-5104",
number = "2",

}

Winters, SL, Gomes, JA, Ip, J, Banas, JS, Shagong, U & Camunas, J 1992, 'Management of cardiac arrhythmias: Physiologic pacing in 1992', Primary Cardiology, vol. 18, no. 2, pp. 42-55.

Management of cardiac arrhythmias : Physiologic pacing in 1992. / Winters, S. L.; Gomes, J. A.; Ip, J.; Banas, J. S.; Shagong, U.; Camunas, J.

In: Primary Cardiology, Vol. 18, No. 2, 01.01.1992, p. 42-55.

Research output: Contribution to journalReview article

TY - JOUR

T1 - Management of cardiac arrhythmias

T2 - Physiologic pacing in 1992

AU - Winters, S. L.

AU - Gomes, J. A.

AU - Ip, J.

AU - Banas, J. S.

AU - Shagong, U.

AU - Camunas, J.

PY - 1992/1/1

Y1 - 1992/1/1

N2 - Dual-chamber DDD-mode pacing has become the universal cardiac pacing mode. While dual-chamber pacemakers were gaining acceptance, adaptive-rate pacing was being developed. Adaptive-rate pacemakers increase pacing rates either when atrial activity cannot be sensed or when sinus node chronotropic incompetence is present. The most commonly used sensors are piezoelectric crystals, which respond to muscle vibrations; metabolic-responsive sensors, which sense changes in minute volume; and temperature sensors, which respond to changes in central venous temperature.

AB - Dual-chamber DDD-mode pacing has become the universal cardiac pacing mode. While dual-chamber pacemakers were gaining acceptance, adaptive-rate pacing was being developed. Adaptive-rate pacemakers increase pacing rates either when atrial activity cannot be sensed or when sinus node chronotropic incompetence is present. The most commonly used sensors are piezoelectric crystals, which respond to muscle vibrations; metabolic-responsive sensors, which sense changes in minute volume; and temperature sensors, which respond to changes in central venous temperature.

UR - http://www.scopus.com/inward/record.url?scp=0026589678&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026589678&partnerID=8YFLogxK

M3 - Review article

AN - SCOPUS:0026589678

VL - 18

SP - 42

EP - 55

JO - Primary Cardiology

JF - Primary Cardiology

SN - 0363-5104

IS - 2

ER -

Winters SL, Gomes JA, Ip J, Banas JS, Shagong U, Camunas J. Management of cardiac arrhythmias: Physiologic pacing in 1992. Primary Cardiology. 1992 Jan 1;18(2):42-55.