Radiation dose from coronary computed tomographic angiography may be decreased using a sequential scanning protocol rather than a conventional helical scanning protocol. We compared radiation dose and image quality from coronary computed tomographic angiography in a single center between an initial period during which helical scanning with electrocardiographically controlled tube current modulation was used for all patients (n = 138) and after adoption of a strategy incorporating sequential scanning whenever appropriate (n = 261). Using the sequential-if-appropriate strategy, sequential scanning was employed in 86.2% of patients. Compared to the helical-only strategy, this strategy was associated with a 65.1% dose decrease (mean dose-length product [DLP] 305.2 vs 875.1 and mean effective dose 14.9 vs 5.2 mSv, respectively), with no significant change in overall image quality, step artifacts, motion artifacts, or perceived image noise. For the 225 patients undergoing sequential scanning, the DLP was 201.9 ± 90.0 mGy × cm; for patients undergoing helical scanning under either strategy, the DLP was 890.9 ± 293.3 mGy × cm (p <0.0001), corresponding to mean effective doses of 3.4 and 15.1 mSv, respectively, a 77.5% decrease. Image quality was significantly greater for the sequential studies, reflecting the poorer image quality in patients undergoing helical scanning in the sequential-if-appropriate strategy. In conclusion, a sequential-if-appropriate diagnostic strategy decreases dose markedly compared to a helical-only strategy, with no significant difference in image quality.

Original languageEnglish (US)
Pages (from-to)1343-1350
Number of pages8
JournalAmerican Journal of Cardiology
Volume104
Issue number10
DOIs
StatePublished - Nov 15 2009
Externally publishedYes

Fingerprint

Angiography
Radiation
Artifacts

All Science Journal Classification (ASJC) codes

  • Cardiology and Cardiovascular Medicine

Cite this

Einstein, Andrew J. ; Wolff, Steven D. ; Manheimer, Eric D. ; Thompson, James ; Terry, Sylvia ; Uretsky, Seth ; Pilip, Adalbert ; Peters, M. Robert. / Comparison of Image Quality and Radiation Dose of Coronary Computed Tomographic Angiography Between Conventional Helical Scanning and a Strategy Incorporating Sequential Scanning. In: American Journal of Cardiology. 2009 ; Vol. 104, No. 10. pp. 1343-1350.
@article{f2f408a37a484671a02567dcc806a5b5,
title = "Comparison of Image Quality and Radiation Dose of Coronary Computed Tomographic Angiography Between Conventional Helical Scanning and a Strategy Incorporating Sequential Scanning",
abstract = "Radiation dose from coronary computed tomographic angiography may be decreased using a sequential scanning protocol rather than a conventional helical scanning protocol. We compared radiation dose and image quality from coronary computed tomographic angiography in a single center between an initial period during which helical scanning with electrocardiographically controlled tube current modulation was used for all patients (n = 138) and after adoption of a strategy incorporating sequential scanning whenever appropriate (n = 261). Using the sequential-if-appropriate strategy, sequential scanning was employed in 86.2{\%} of patients. Compared to the helical-only strategy, this strategy was associated with a 65.1{\%} dose decrease (mean dose-length product [DLP] 305.2 vs 875.1 and mean effective dose 14.9 vs 5.2 mSv, respectively), with no significant change in overall image quality, step artifacts, motion artifacts, or perceived image noise. For the 225 patients undergoing sequential scanning, the DLP was 201.9 ± 90.0 mGy × cm; for patients undergoing helical scanning under either strategy, the DLP was 890.9 ± 293.3 mGy × cm (p <0.0001), corresponding to mean effective doses of 3.4 and 15.1 mSv, respectively, a 77.5{\%} decrease. Image quality was significantly greater for the sequential studies, reflecting the poorer image quality in patients undergoing helical scanning in the sequential-if-appropriate strategy. In conclusion, a sequential-if-appropriate diagnostic strategy decreases dose markedly compared to a helical-only strategy, with no significant difference in image quality.",
author = "Einstein, {Andrew J.} and Wolff, {Steven D.} and Manheimer, {Eric D.} and James Thompson and Sylvia Terry and Seth Uretsky and Adalbert Pilip and Peters, {M. Robert}",
year = "2009",
month = "11",
day = "15",
doi = "10.1016/j.amjcard.2009.07.003",
language = "English (US)",
volume = "104",
pages = "1343--1350",
journal = "American Journal of Cardiology",
issn = "0002-9149",
publisher = "Elsevier Inc.",
number = "10",

}

Comparison of Image Quality and Radiation Dose of Coronary Computed Tomographic Angiography Between Conventional Helical Scanning and a Strategy Incorporating Sequential Scanning. / Einstein, Andrew J.; Wolff, Steven D.; Manheimer, Eric D.; Thompson, James; Terry, Sylvia; Uretsky, Seth; Pilip, Adalbert; Peters, M. Robert.

In: American Journal of Cardiology, Vol. 104, No. 10, 15.11.2009, p. 1343-1350.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Comparison of Image Quality and Radiation Dose of Coronary Computed Tomographic Angiography Between Conventional Helical Scanning and a Strategy Incorporating Sequential Scanning

AU - Einstein, Andrew J.

AU - Wolff, Steven D.

AU - Manheimer, Eric D.

AU - Thompson, James

AU - Terry, Sylvia

AU - Uretsky, Seth

AU - Pilip, Adalbert

AU - Peters, M. Robert

PY - 2009/11/15

Y1 - 2009/11/15

N2 - Radiation dose from coronary computed tomographic angiography may be decreased using a sequential scanning protocol rather than a conventional helical scanning protocol. We compared radiation dose and image quality from coronary computed tomographic angiography in a single center between an initial period during which helical scanning with electrocardiographically controlled tube current modulation was used for all patients (n = 138) and after adoption of a strategy incorporating sequential scanning whenever appropriate (n = 261). Using the sequential-if-appropriate strategy, sequential scanning was employed in 86.2% of patients. Compared to the helical-only strategy, this strategy was associated with a 65.1% dose decrease (mean dose-length product [DLP] 305.2 vs 875.1 and mean effective dose 14.9 vs 5.2 mSv, respectively), with no significant change in overall image quality, step artifacts, motion artifacts, or perceived image noise. For the 225 patients undergoing sequential scanning, the DLP was 201.9 ± 90.0 mGy × cm; for patients undergoing helical scanning under either strategy, the DLP was 890.9 ± 293.3 mGy × cm (p <0.0001), corresponding to mean effective doses of 3.4 and 15.1 mSv, respectively, a 77.5% decrease. Image quality was significantly greater for the sequential studies, reflecting the poorer image quality in patients undergoing helical scanning in the sequential-if-appropriate strategy. In conclusion, a sequential-if-appropriate diagnostic strategy decreases dose markedly compared to a helical-only strategy, with no significant difference in image quality.

AB - Radiation dose from coronary computed tomographic angiography may be decreased using a sequential scanning protocol rather than a conventional helical scanning protocol. We compared radiation dose and image quality from coronary computed tomographic angiography in a single center between an initial period during which helical scanning with electrocardiographically controlled tube current modulation was used for all patients (n = 138) and after adoption of a strategy incorporating sequential scanning whenever appropriate (n = 261). Using the sequential-if-appropriate strategy, sequential scanning was employed in 86.2% of patients. Compared to the helical-only strategy, this strategy was associated with a 65.1% dose decrease (mean dose-length product [DLP] 305.2 vs 875.1 and mean effective dose 14.9 vs 5.2 mSv, respectively), with no significant change in overall image quality, step artifacts, motion artifacts, or perceived image noise. For the 225 patients undergoing sequential scanning, the DLP was 201.9 ± 90.0 mGy × cm; for patients undergoing helical scanning under either strategy, the DLP was 890.9 ± 293.3 mGy × cm (p <0.0001), corresponding to mean effective doses of 3.4 and 15.1 mSv, respectively, a 77.5% decrease. Image quality was significantly greater for the sequential studies, reflecting the poorer image quality in patients undergoing helical scanning in the sequential-if-appropriate strategy. In conclusion, a sequential-if-appropriate diagnostic strategy decreases dose markedly compared to a helical-only strategy, with no significant difference in image quality.

UR - http://www.scopus.com/inward/record.url?scp=71749092079&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=71749092079&partnerID=8YFLogxK

U2 - 10.1016/j.amjcard.2009.07.003

DO - 10.1016/j.amjcard.2009.07.003

M3 - Article

VL - 104

SP - 1343

EP - 1350

JO - American Journal of Cardiology

JF - American Journal of Cardiology

SN - 0002-9149

IS - 10

ER -